Texas Instruments /MSP432P401Y /TIMER_A2 /TAxCCTL[2]

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as TAxCCTL[2]

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (CCIFG_0)CCIFG 0 (COV_0)COV 0 (OUT_0)OUT 0 (CCI)CCI 0 (CCIE_0)CCIE 0 (OUTMOD_0)OUTMOD 0 (CAP_0)CAP 0 (SCCI)SCCI 0 (SCS_0)SCS 0 (CCIS_0)CCIS 0 (CM_0)CM

CCIFG=CCIFG_0, OUTMOD=OUTMOD_0, CCIE=CCIE_0, OUT=OUT_0, SCS=SCS_0, CCIS=CCIS_0, CAP=CAP_0, COV=COV_0, CM=CM_0

Description

Timer_A Capture/Compare Control Register

Fields

CCIFG

Capture/compare interrupt flag

0 (CCIFG_0): No interrupt pending

1 (CCIFG_1): Interrupt pending

COV

Capture overflow

0 (COV_0): No capture overflow occurred

1 (COV_1): Capture overflow occurred

OUT

Output

0 (OUT_0): Output low

1 (OUT_1): Output high

CCI

Capture/compare input

CCIE

Capture/compare interrupt enable

0 (CCIE_0): Interrupt disabled

1 (CCIE_1): Interrupt enabled

OUTMOD

Output mode

0 (OUTMOD_0): OUT bit value

1 (OUTMOD_1): Set

2 (OUTMOD_2): Toggle/reset

3 (OUTMOD_3): Set/reset

4 (OUTMOD_4): Toggle

5 (OUTMOD_5): Reset

6 (OUTMOD_6): Toggle/set

7 (OUTMOD_7): Reset/set

CAP

Capture mode

0 (CAP_0): Compare mode

1 (CAP_1): Capture mode

SCCI

Synchronized capture/compare input

SCS

Synchronize capture source

0 (SCS_0): Asynchronous capture

1 (SCS_1): Synchronous capture

CCIS

Capture/compare input select

0 (CCIS_0): CCIxA

1 (CCIS_1): CCIxB

2 (CCIS_2): GND

3 (CCIS_3): VCC

CM

Capture mode

0 (CM_0): No capture

1 (CM_1): Capture on rising edge

2 (CM_2): Capture on falling edge

3 (CM_3): Capture on both rising and falling edges

Links

() ()